The work
What an outside tap quote should include
An outside tap quote should name the tap position, the cold supply it tees into, the backflow check valve, an indoor isolating valve and drain point, the wall hole and its sealing, and frost protection. It should show how garden water is kept out of the drinking water supply. Fitting time on a weekday is £95 an hour, one hour minimum, and the parts are extra.
Backflow
A hose left in a bucket, pond or sprayer can allow dirty water to be drawn back. The Water Supply (Water Fittings) Regulations require suitable backflow prevention, and for a domestic hose tap that is commonly a double check valve. Water Regs UK's guidance for buildings newer than 1 July 1999 is to fit the double check valve for a category 3 hose tap indoors, with frost protection where needed. Ask for the device type and position by name. A garden watering system that is not designed to be operated by hand is one the water company has to hear about before installation starts.
Choosing the position
The easiest route is usually near an internal cold pipe, with a short run through an external wall. A tap across the garden needs buried pipe, and external pipe laid shallower than 750mm or deeper than 1350mm appears in the same notification table. Think about drainage beneath the tap, doors that might hit it and how a hose will reel.
Lines to put on the quote
- Tap location and height.
- Cold supply to be teed into.
- Indoor isolating valve and drain point.
- Check valve.
- Wall sleeve and sealing around the hole.
- Pipe material and insulation.
- Buried sections, excavation and surface repair, if any.
- Who confirms hidden cables and pipes are clear of the drilling point.
Details to send
Pictures inside and outside the wall, the distance between the pipe and wanted position, wall construction and whether the supply is metered or shared. Tenants and leaseholders should obtain written consent before anyone drills; conservation or listed status may add limits.
Type the details into the form and send the pictures to info@honestplumberlondon.co.uk by email.
Changing an existing tap
If a tap is already there, ask whether the visit covers repair, replacement or adding the missing protection and indoor valve. Older installations may lack a check valve altogether. A leaking spindle, a split pipe after frost and a loose wall bracket are separate faults, so describe each and have the quote say which will be dealt with and which only inspected.
The figures to expect on your quote
- Weekdays: £95 an hour, with one hour as the minimum.
- Evenings and weekends: from £140 an hour.
Booked in advance means no call-out fee. An emergency visit can be requested at any hour of any day: a weekday daytime visit costs the hourly rate plus a £60 call-out, and an evening or weekend visit costs from £140 an hour plus £60. Parts are charged on top after you approve them, VAT is not added, and a written quote costs nothing. Last checked 28 November 2026; see what you pay.
Acceptance
Open the tap fully and check flow. Close it and confirm it does not drip. Operate the indoor valve and verify that it stops the outside supply. Inspect indoor joints with the pressure on, and look at the sealed hole from both sides. Ask the installer to show where the check valve is.
Before winter
Close the inside valve, open the outside tap to empty the pipe, drain it if there is a drain point and leave the tap open while the supply stays off. Remove hoses. Make a note near the indoor valve saying what it controls, so that whoever finds it in a hurry does not turn the wrong one.
Questions people ask
Does an outside tap need a check valve?
Backflow protection is required by the Water Fittings Regulations, and for a domestic hose tap that is commonly a double check valve. Ask for the device and its position by name.
Do I need the water company's consent for garden pipework?
Some work needs notice first, including a garden watering system not designed to be operated by hand and outside pipe laid shallower than 750mm or deeper than 1350mm.