The work
Unvented storage: upkeep, faults and swaps
Unvented cylinder work goes only to G3 qualified engineers. Ask for it to be described component by component, with the safety controls that will be tested or changed named on the quote. Weekday labour is £95 an hour, one hour minimum.
Photograph the cylinder's label and every valve before you ask. A sealed hot water store at mains pressure relies on several safety controls acting together.
Who may work on it
These jobs are given to G3 qualified engineers and to nobody else, with cylinder specialists on hand. Before any cover comes off, have your visitor prove that qualification to you. If the cylinder is heated by a gas boiler and gas work is involved, the gas portion needs a Gas Safe registered engineer, no exceptions: match their card against the Gas Safe Register.
Warning signs
Water or steam from the discharge pipe or tundish, a relief valve that keeps running, very hot water at taps, bulging, or noises from the vessel need prompt attention. Switch off the heat source if you can do so safely and keep clear of hot discharge. Never cap, plug or tie up a valve or pipe to stop it.
Servicing
Follow the manufacturer's interval. Ask the record to cover the pressure reducing valve, strainer, expansion vessel or air gap, expansion relief, temperature and pressure relief, thermostats, cut-outs and discharge pipework, with anything adjusted or replaced.
Replacement
- Capacity, material and model, with reasons.
- Matching safety valve set from the manufacturer.
- Discharge route, pipe size and visible tundish.
- Incoming mains flow and pressure, with measured figures.
- Immersion, boiler coil or heat pump connections.
- Floor loading, cupboard alterations and access.
- Removal and disposal of the old vessel.
- Time without hot water.
Building regulations
Approved Document G addresses hot water safety, and installing an unvented system is generally notifiable. Write down who notifies building control and which certificate you will be given.
Describing a fault
Say whether discharge happens during heating or all the time, whether hot water pressure changed, which heat source was running and when the last service was. Note error lights on controls. Do not drain, recharge or adjust any component to test your own theory.
The figures to expect on your quote
- Weekdays: £95 an hour, with one hour as the minimum.
- Evenings and weekends: from £140 an hour.
Booked in advance means no call-out fee. An emergency visit can be requested at any hour of any day: a weekday daytime visit costs the hourly rate plus a £60 call-out, and an evening or weekend visit costs from £140 an hour plus £60. Parts are charged on top after you approve them, VAT is not added, and a written quote costs nothing. Last checked 28 November 2026; see what you pay.
Flats
Where the discharge route or supply is shared, ask the managing agent what consent is needed and send it with the request. A new termination point on an outside wall may also need approval.
Handover
Watch the cylinder through a full heat cycle with the engineer if possible. The discharge should stay dry in normal use. Keep the commissioning sheet, benchmark or service record, warranty terms and building control certificate in one place, and enter the next service date. For the wider choice between types, see hot water cylinders.
Questions people ask
What does water from the discharge pipe mean?
It needs prompt attention. Switch off the heat source if safe, keep clear of hot water and never cap or tie up the valve or pipe.
What should a service record cover?
Ask for the pressure reducing valve, strainer, expansion provision, relief valves, thermostats, cut-outs and discharge pipework, with anything adjusted or replaced.